5 Reasons Your Ground-Fault Circuit Interrupter Outlets Keeps Tripping. Legrand ev charger

Reasons Your Ground-Fault Circuit Interrupter Outlets Keeps Tripping

Ground-fault circuit interrupters are designed for your safety. Circuit interrupters, or trips as they are commonly referred to, are intended to reduce the risk of fire or electrocution. If they trip, it’s an indication there is a problem and you’ll need an electrician you can trust.

What Causes Ground-Fault Circuit Interrupter To Trip?

The top five reasons your GFCI outlet keeps tripping are ground-fault occurrences, moisture in the receptacle box, an overloaded circuit, an electrical fault, and a faulty GFCI outlet. We’ll cover each of these issues, including causes and solutions.

Ground-Fault Occurrence

Ground faults occur when the hot wire or live wire comes into contact with the ground wire or the grounded area of an appliance. Usually, GFCIs function by detecting when the current is flowing along an unintended path (e.g., through water or a person).

The instant the GFCI detects there is even the slightest of current leakage as low as 0.005 amps, it trips right away.

How do you determine if the current is leaking? Unplug everything on that circuit and make sure all the switches are off. Check for any wear that may have occurred to the equipment. Any slight damage means the electrical part is no longer protected from contact.

Moisture in the Receptacle Box

The accumulation of moisture is another major cause of GFCI tripping. Outdoor GFCI outlets are the most vulnerable, and rain is the most common culprit. However, due to the tropical climate of Florida, high humidity can also cause moisture buildup and make it harder for any water trapped in a receptacle box to evaporate.

Start your search by inspecting the receptacle box. Be sure to turn off the breaker before opening the box containing the receptacle. The box must be dry before you attempt to reset the GFCI. It is possible to speed up this drying process using a simple tool such as a blow dryer, but that part is best left to a professional.

If the installation is outdoors or located in high humidity areas, such as the bathroom or kitchen, make sure the box is weatherproof and locked even when the receptor is in use. The presence of moisture can expose you to the risk of accidental electric shock.

Overloaded Circuit

Circuit overload occurs when more amperage flows through an electric wire or circuit than it can handle. This may happen if you connect malfunctioning or defective appliances. Loose, corroded wires or connections may also be to blame. Once the GFCI outlet senses an overload, it trips or breaks the circuit.

If you want to determine if overloading is really the problem, follow these steps in order.

  • Unplug all the appliances connected to the circuit in question
  • Reset the circuit on your fuse box
  • Wait several minutes
  • Plug an appliance back in and turn it on
  • Check to see that your circuit has not tripped
  • Plug in the next appliance, turn it on, check the breaker, and so on

You may find you’ll need to replace the items causing the problem.

If the problem keeps reoccurring, you may need a new dedicated circuit and outlet that can handle the amperage required by the appliances.

Electrical Fault

If your GFCI outlet trips consistently, it could be an electric fault resulting from faulty structural wiring. An electrical outlet connected to the same circuit could also be the source of the problem, especially if it was not part of the original wiring of your home. In the case of an electrical fault, you will need a professional electrician to fix the problem.

Faulty GFCI Outlet

If you’ve tried all else and the GFCI outlet reset doesn’t solve the problem, that means the outlet itself is defective. GFCI outlets have highly responsive internal circuitry to detect whenever there’s a flaw in the electric system. With time, the sensitive circuitry wears out, rendering the outlet dysfunctional. In this case, the outlet will need repairing or even replacing and should be done by a qualified electrician.

Find an Electrician You Trust

David Gray Electrical Services offers a range of commercial and electric services. We have highly trained, licensed, and equipped technicians. If you’re experiencing GFCI outlet tripping issues in the Jacksonville area, contact us to schedule an appointment.

legrand 057012 Green Up One Wallbox Charging Station User Guide

Home » Legrand » legrand 057012 Green Up One Wallbox Charging Station User Guide

0 570 10. …. 0 570 17EV Charging StationPart: LERAK135B_20221004

reasons, your, ground-fault, circuit, interrupter, outlets

Overview of the Charging Station

Available features depend on the charging station model.

Safety Instructions

WARNINGDanger of electric shock! Risk of fire!

  • People who are not able to operate according to the instructions must not use this charging station.
  • Do not use this charging station, if the charging station itself or the charging cable appears to be damaged.
  • The installation must only be done by a qualified professional.

Intended Use

  • The charging station is intended for charging electric vehicles, both plug-in hybrids and full battery electric vehicles.
  • Do not connect to the charging station other devices, such as power tools.

Fixed Charging Cable

The charging stations are equipped with a fixed charging cable.

Charging in “Authorized” Mode

Start charging

  • Remove the plug from the plug holder.
  • Plug in your electric vehicle.
  • Open the Charger Control application on your mobile device.
  • Press “Start” on the application.
  • Open the Charger Control application on your mobile device.
  • Press “Stop” on the application.
  • Unplug your electric vehicle.
  • Put the plug back into the plug holder.

Load Management

8.1. Dynamic Load ManagementYou can use this feature if a compatible energy meter is connected to your charging station and to your property’s electrical supply.The energy meter measures the total power consumption in your property. If some other load over the set maximum current for load management is added when charging is ongoing, the charging station will decrease the charging current. If the total power consumption reaches the allowed maximum power of your property, the charging interrupts until the total power consumption has decreased to a value at which the charging can continue.You can see the real time charging current from the Charger Control Application.You can enable / disable this feature from the Charger Control Application.

8.2. External ControlYou can use this feature if an external control device is connected to your charging station. The override function depends on the connected devices. It can be for example a load management system for your entire property or a switch or a timer that controls your charging station. Please study the user instructions for the connected devices. You can enable / disable this feature from the Charger Control Application.

Maintenance/Preventive Maintenance Instructions

Do these maintenance actions once a year or as necessary. With well-done maintenance you can ensure a long lifetime of the charging station and keep the warranty valid.

X Maintenance actionClean possible dirt and dust from the surface of the charging station. Wipe carefully with a moist cloth.Examine the charging plug and the charging cable for wear out or mechanical damage.The charging plug and cable must only be replaced by a qualified professional.Software update, if necessary. The software update takes at least 15 – 20 minutes.Do not switch off the power or use the charging station during the update.Test the residual current device. Comply local requirements for testing interval, but test the device at least once every six months.

Residual Current Device Testing Instructions

0 570 10/0 570 12/0 570 14/0 570 16:Test the residual current device at the supply line.0 570 11 / 0 570 13 / 0 570 15 / 0 570 17:

  • The combined device with residual current circuit breaker and over current protection (RCBO) is located in the installation box.
  • Open the installation box hatch.
  • Press the TEST button.
  • The rocker turns to 0 position.
  • Turn the rocker back to I position.
  • If a fault occurs, contact an electrician.

Warranty

Check the validity and duration of warranty with LEGRAND’s local sales representative.

Declaration of Conformity

Hereby, LEGRAND declares that the charging stations 0 570 10. …. 0 570 17 are in compliance with the Directive 2014/53/EU.The full text of the EU declaration of conformity is available on request. Please see contact information on www.legrand.com

Disposal

Do not dispose of electrical and electronic devices including their accessories with the household waste.

  • When the charging station is at the end of its life cycle, it must be disposed of properly according to local recycling guidelines.
  • The charging station’s cardboard packing is suitable for recycling.
  • Dispose of the plastic wrap with the household waste or according to local recycling guidelines.

Charger Control Application

  • With the Charger Control application you can control your charging station and change the settings of your charging station.
  • Bluetooth technology is used for the wireless connection.
  • The range in free space is approximately 5m.Note! Do not change the settings while charging is in progress.

14.1. Installing the application

Android version 5.0 and above

https://apps.Apple.com/fi/app/ensto-charger-control/id1449138889

iOS version 8.0 and above

https://play.google.com/store/apps/details?ID=com.homechargermobile

14.2. Pairing the charging station with your mobile device

  • First switch off the charging station from the main switch and then switch it on again.
  • Start the pairing procedure within 3 minutes.
  • Open the application.
  • Go to “Devices”.
  • Select from “Discovered Devices” the charging station you want to pair with your mobile.
  • If the pairing fails the first time, try again starting from step 1.
  • When the pairing is completed, you can find your charging station in “Devices / My Devices”.

Up to 8 mobile devices can be paired to the charging station. Obey the pairing procedure above for every new mobile device. Re-boot (power on / power off ) is required also if you want to introduce another mobile application to the harging station.Only one mobile device can be connected to the charging station. The charging station is shown grey on other paired mobile devices, which are within the Bluetooth range.When you unpair an iOS device, it must also be manually removed from the charging station’s Bluetooth settings.14.3. Application user interface

Note! If you have a 3-phase charging station (0 570 14, 0 570 16, 0 570 15, 0 570 17) and all phases are connected, the application shows the highest charging current and the charged energy is calculated from that value. The actual total charged energy may be lower than calculated.PRODo not change the settings marked with PRO. These settings must only be changed by a qualified professional.

14.4. Changing the operating mode

  • The default setting for the charging station is “Free charging”.
  • You can change the operating mode to “Authorized” in “Settings/Charger/Operation mode”.
  • In the “Authorized” mode you start and stop charging with the application.
  • The nominal charging current depends on the charging station model.
  • If your installer has set the maximum charging current to a lower value, it is due to restrictions on the installation site.
  • You can charge your vehicle at a lower current than the set maximum value. Notice that in that case it takes longer to charge your vehicle fully.
  • You can set the charging current from the home screen or “Settings/ Charger/ Max. charging current”.

14.6. Property energy meterYou can enable / disable the external meter from “Settings/Load Management/Property energy meter”.14.7. External controlYou can enable / disable the override mode from “Settings/Load Management/External control (Dry contact)”.14.8. Error messagesAt error state, an error code appears on the screen of your mobile device. If you need to contact LEGRAND related to faulty operation of the charging station, go first to “Settings/Charger/Error log”. Save the error log information before contacting. This information helps the technical support and maintenance to resolve the issue.Note! In some situations the charging station automatically returns to normal operation within approximately minutes after disconnecting the charging cable.Please see the following table for the cause and corrective actions.

legrand 057012 Green Up One Wallbox Charging Station User Guide

Home » Legrand » legrand 057012 Green Up One Wallbox Charging Station User Guide

0 570 10. …. 0 570 17EV Charging StationPart: LERAK135B_20221004

Overview of the Charging Station

Available features depend on the charging station model.

Safety Instructions

WARNINGDanger of electric shock! Risk of fire!

  • People who are not able to operate according to the instructions must not use this charging station.
  • Do not use this charging station, if the charging station itself or the charging cable appears to be damaged.
  • The installation must only be done by a qualified professional.

Intended Use

  • The charging station is intended for charging electric vehicles, both plug-in hybrids and full battery electric vehicles.
  • Do not connect to the charging station other devices, such as power tools.

Fixed Charging Cable

The charging stations are equipped with a fixed charging cable.

Charging in “Authorized” Mode

Start charging

  • Remove the plug from the plug holder.
  • Plug in your electric vehicle.
  • Open the Charger Control application on your mobile device.
  • Press “Start” on the application.
  • Open the Charger Control application on your mobile device.
  • Press “Stop” on the application.
  • Unplug your electric vehicle.
  • Put the plug back into the plug holder.

Load Management

8.1. Dynamic Load ManagementYou can use this feature if a compatible energy meter is connected to your charging station and to your property’s electrical supply.The energy meter measures the total power consumption in your property. If some other load over the set maximum current for load management is added when charging is ongoing, the charging station will decrease the charging current. If the total power consumption reaches the allowed maximum power of your property, the charging interrupts until the total power consumption has decreased to a value at which the charging can continue.You can see the real time charging current from the Charger Control Application.You can enable / disable this feature from the Charger Control Application.

8.2. External ControlYou can use this feature if an external control device is connected to your charging station. The override function depends on the connected devices. It can be for example a load management system for your entire property or a switch or a timer that controls your charging station. Please study the user instructions for the connected devices. You can enable / disable this feature from the Charger Control Application.

Maintenance/Preventive Maintenance Instructions

Do these maintenance actions once a year or as necessary. With well-done maintenance you can ensure a long lifetime of the charging station and keep the warranty valid.

X Maintenance actionClean possible dirt and dust from the surface of the charging station. Wipe carefully with a moist cloth.Examine the charging plug and the charging cable for wear out or mechanical damage.The charging plug and cable must only be replaced by a qualified professional.Software update, if necessary. The software update takes at least 15 – 20 minutes.Do not switch off the power or use the charging station during the update.Test the residual current device. Comply local requirements for testing interval, but test the device at least once every six months.

Residual Current Device Testing Instructions

0 570 10/0 570 12/0 570 14/0 570 16:Test the residual current device at the supply line.0 570 11 / 0 570 13 / 0 570 15 / 0 570 17:

  • The combined device with residual current circuit breaker and over current protection (RCBO) is located in the installation box.
  • Open the installation box hatch.
  • Press the TEST button.
  • The rocker turns to 0 position.
  • Turn the rocker back to I position.
  • If a fault occurs, contact an electrician.

Warranty

Check the validity and duration of warranty with LEGRAND’s local sales representative.

Declaration of Conformity

Hereby, LEGRAND declares that the charging stations 0 570 10. …. 0 570 17 are in compliance with the Directive 2014/53/EU.The full text of the EU declaration of conformity is available on request. Please see contact information on www.legrand.com

Disposal

Do not dispose of electrical and electronic devices including their accessories with the household waste.

  • When the charging station is at the end of its life cycle, it must be disposed of properly according to local recycling guidelines.
  • The charging station’s cardboard packing is suitable for recycling.
  • Dispose of the plastic wrap with the household waste or according to local recycling guidelines.

Charger Control Application

  • With the Charger Control application you can control your charging station and change the settings of your charging station.
  • Bluetooth technology is used for the wireless connection.
  • The range in free space is approximately 5m.Note! Do not change the settings while charging is in progress.

14.1. Installing the application

Android version 5.0 and above

https://apps.Apple.com/fi/app/ensto-charger-control/id1449138889

reasons, your, ground-fault, circuit, interrupter, outlets

iOS version 8.0 and above

https://play.google.com/store/apps/details?ID=com.homechargermobile

14.2. Pairing the charging station with your mobile device

  • First switch off the charging station from the main switch and then switch it on again.
  • Start the pairing procedure within 3 minutes.
  • Open the application.
  • Go to “Devices”.
  • Select from “Discovered Devices” the charging station you want to pair with your mobile.
  • If the pairing fails the first time, try again starting from step 1.
  • When the pairing is completed, you can find your charging station in “Devices / My Devices”.

Up to 8 mobile devices can be paired to the charging station. Obey the pairing procedure above for every new mobile device. Re-boot (power on / power off ) is required also if you want to introduce another mobile application to the harging station.Only one mobile device can be connected to the charging station. The charging station is shown grey on other paired mobile devices, which are within the Bluetooth range.When you unpair an iOS device, it must also be manually removed from the charging station’s Bluetooth settings.14.3. Application user interface

Note! If you have a 3-phase charging station (0 570 14, 0 570 16, 0 570 15, 0 570 17) and all phases are connected, the application shows the highest charging current and the charged energy is calculated from that value. The actual total charged energy may be lower than calculated.PRODo not change the settings marked with PRO. These settings must only be changed by a qualified professional.

14.4. Changing the operating mode

  • The default setting for the charging station is “Free charging”.
  • You can change the operating mode to “Authorized” in “Settings/Charger/Operation mode”.
  • In the “Authorized” mode you start and stop charging with the application.
  • The nominal charging current depends on the charging station model.
  • If your installer has set the maximum charging current to a lower value, it is due to restrictions on the installation site.
  • You can charge your vehicle at a lower current than the set maximum value. Notice that in that case it takes longer to charge your vehicle fully.
  • You can set the charging current from the home screen or “Settings/ Charger/ Max. charging current”.

14.6. Property energy meterYou can enable / disable the external meter from “Settings/Load Management/Property energy meter”.14.7. External controlYou can enable / disable the override mode from “Settings/Load Management/External control (Dry contact)”.14.8. Error messagesAt error state, an error code appears on the screen of your mobile device. If you need to contact LEGRAND related to faulty operation of the charging station, go first to “Settings/Charger/Error log”. Save the error log information before contacting. This information helps the technical support and maintenance to resolve the issue.Note! In some situations the charging station automatically returns to normal operation within approximately minutes after disconnecting the charging cable.Please see the following table for the cause and corrective actions.

Leave a Comment